Home > Connectors > Delta Fans Replacement > Delta EFB0412VHD-R00 12V 40mm Cooling Fan

Delta EFB0412VHD-R00 12V 40mm Cooling Fan

2026-08-27 10:49:26 DataStorage View times 3
Delta EFB0412VHD-R00 12V 40mm Cooling Fan
Part Number: EFB0412VHD-R00

Manufacturer: Delta Electronics

Series: EFB

Product Type: DC axial cooling fan
Rated Voltage: 12V DC
Frame Size: 40 × 40 × 20mm
Bearing Type: Ball bearing
Monitoring Function: Locked-rotor sensor
Termination: 3 lead wires
Part Status: Active
Stock: Contact us for current availability and lead time
RFQ

Delta EFB0412VHD-R00 12V 40mm Cooling Fan

The EFB0412VHD-R00 is a compact DC axial cooling fan from Delta Electronics’ EFB series. It operates from a nominal 12V DC supply and uses a 40 × 40 × 20mm square frame with a ball-bearing system.

At a maximum speed of 9,000 RPM, the fan delivers up to 10.10 CFM airflow and 0.416 inchH₂O static pressure. Its compact dimensions and pressure capability make it suitable for servers, network equipment, embedded computers, power supplies and other space-constrained electronic systems.

The R00 version has three lead wires and includes a locked-rotor sensor, allowing the host system to detect when the fan has stopped or cannot rotate normally. It does not provide PWM speed control. 

Technical Specifications

ParameterSpecification
Rated voltage12V DC
Operating voltage range7.0–13.8V DC
Rated current0.12A
Rated power1.44W
Frame dimensions40 × 40 × 20mm
Fan typeDC axial fan
Maximum speed9,000 RPM
Maximum airflow10.10 CFM / 0.286m³/min
Maximum static pressure0.416 inchH₂O / 10.57mmH₂O
Noise level32.5dB(A)
Bearing typeBall bearing
Monitoring functionLocked-rotor sensor
Termination3 lead wires
Operating temperature−10°C to +70°C
Expected lifetime70,000 hours at 40°C
WeightApproximately 33g
Frame materialPlastic
Blade materialPlastic
Ingress protectionNot specified

Airflow and static pressure are maximum values measured at different points on the fan performance curve. Actual airflow depends on the resistance of the equipment’s heat sink, grille, filter and internal ventilation path.

Typical Applications

The Delta EFB0412VHD-R00 can be used in:

  • 1U servers and compact computing systems

  • Network switches, routers and security appliances

  • RAID, NAS and data-storage equipment

  • Embedded computers and edge devices

  • Telecom modules and communication equipment

  • Compact power supplies and DC converters

  • Industrial controllers and automation equipment

  • Test and measurement instruments

  • Small electronic enclosures

  • Replacement of failed EFB0412VHD-R00 fans

Locked-Rotor Sensor Function

The third lead wire on the EFB0412VHD-R00 provides a locked-rotor detection signal. This function can help the equipment controller identify conditions such as:

  • Fan obstruction

  • Impeller lock

  • Fan motor failure

  • Abnormal fan stoppage

The host system can use this signal to generate a cooling alarm, shut down equipment or activate a redundant fan.

A locked-rotor sensor is not the same as a tachometer output. It is intended primarily to indicate whether the fan is rotating or locked, rather than provide continuous RPM measurement. The signal interface and pin assignment should be checked against the fan specification and equipment circuit before installation.

Compact High-Speed Cooling

The 40 × 40 × 20mm frame allows the EFB0412VHD-R00 to fit into equipment where installation space is limited. Compared with thinner 40 × 40 × 10mm fans, its 20mm depth supports stronger pressure performance for restrictive airflow paths.

Its maximum static pressure of 10.57mmH₂O is useful for moving air through:

  • Compact heat sinks

  • Closely spaced circuit boards

  • Narrow server air channels

  • Protective grilles

  • Dense power components

  • Restricted enclosure vents

The specified 32.5dB(A) noise level should be considered when the fan is used near operators or in acoustically sensitive equipment.

EFB0412VHD-R00 Replacement Selection

Before replacing the EFB0412VHD-R00, confirm:

  1. Complete part number: EFB0412VHD-R00

  2. Rated voltage: 12V DC

  3. Operating voltage range: 7.0–13.8V DC

  4. Frame dimensions: 40 × 40 × 20mm

  5. Rated current: 0.12A

  6. Three-wire locked-rotor interface

  7. Connector type and pin assignment

  8. Wire length and mounting-hole positions

  9. Airflow and static-pressure requirements

  10. Airflow direction and installation orientation

Fans with the same 40mm frame and 12V rating are not necessarily interchangeable. Differences in thickness, current, airflow, pressure, connector and monitoring signal can affect installation and system operation.

The suffix is particularly important:

  • EFB0412VHD-R00: Locked-rotor sensor

  • EFB0412VHD-F00: A different signal-function version

  • EFB0412VHD: Basic suffix configuration

Do not substitute these versions solely on the basis of voltage and dimensions. Confirm the required signal function and connector wiring before ordering.

Stock, Pricing and Lead Time

DataStorageIC  can assist with sourcing the original Delta EFB0412VHD-R00, compatible suffix versions and technically matched replacement fans.

For an accurate quotation, please provide:

  • Required quantity

  • Target delivery date

  • Shipping destination

  • Clear photograph of the fan label

  • Connector and wire photograph

  • Wire length and pin sequence

  • Equipment model or application

  • Required inspection or traceability documents

Contact us for current stock, price, lead time, datasheet support and replacement-model evaluation.

WhatsApp

WhatsApp

Email

Email

RFQ

RFQ

Facebook

Facebook