Home > solution > Delta High Static Pressure Fans for GPU and AI Servers

Delta High Static Pressure Fans for GPU and AI Servers

2026-08-27 17:14:14 Data Storage Technology Limited View times 9

Delta High Static Pressure Fans for GPU and AI Servers

GPU and AI servers contain high-power processors, accelerator cards, memory modules, power converters and dense heat sinks within a restricted chassis. Moving a large volume of air in free space is not enough; the fan must maintain useful airflow after overcoming the pressure loss created by the complete server.

Delta offers high-static-pressure server fans in its PFR, PFB, GFB, FFB and QFR families. These include compact 38 mm fans for conventional fan walls and deeper PFB-E and GFB-E models for systems with exceptionally high airflow resistance.

Delta High Static Pressure Fans for GPU and AI Servers

Why AI Servers Need High Static Pressure

Cooling air in a GPU server may need to pass through:

  • Front-panel grilles

  • Dust or EMI screens

  • HDD and SSD cages

  • Accelerator cards

  • Dense CPU and GPU heat sinks

  • DIMM banks

  • Power converters

  • Server backplanes

  • Cable assemblies

  • Restricted rear outlets

Every obstruction creates pressure loss. As system resistance increases, the airflow delivered by a general-purpose fan can fall substantially below its free-air CFM rating.

A high-static-pressure fan uses its impeller, motor torque and frame design to maintain airflow against this resistance. This is particularly important in compact 1U and 2U servers where small fans must operate at high speed.

Recommended Delta High-Pressure Server Fans

ModelSizeVoltageSpeedAirflowStatic PressurePowerNoiseInterface
PFR0612XHE-SP0060 × 60 × 38 mm12 VDC16,500 RPM76.16 CFM3.185 inH₂O27.60 W67.7 dB(A)Tachometer, PWM
PFR0812XHE-SP0080 × 80 × 38 mm12 VDC13,300 RPM134.29 CFM3.000 inH₂O42.00 W71.5 dB(A)Tachometer, PWM
PFR0912XHE-SP0092 × 92 × 38 mm12 VDC11,500 RPM185.55 CFM2.523 inH₂O44.40 W71.0 dB(A)Tachometer, PWM
PFR1212DHE-SP00120 × 120 × 38 mm12 VDC7,400 RPM254.34 CFM1.438 inH₂O44.40 W68.5 dB(A)Tachometer, PWM
PFB0812EE-E80 × 80 × 80 mm12 VDC16,800 RPM129.56 CFM6.010 inH₂O48.00 WTachometer, PWM
GFB0412ES-E40 × 40 × 56 mm12 VDC29,500 RPM33.90 CFM6.440 inH₂O39.00 W73.0 dB(A)Tachometer, PWM
GFB0612ES-E60 × 60 × 56 mm12 VDC24,300 RPM76.51 CFM9.730 inH₂O49.80 W82.0 dB(A)Tachometer, PWM
GFB0912ES-E92 × 92 × 56 mm12 VDC11,400 RPM165.44 CFM4.670 inH₂O47.40 W78.5 dB(A)Tachometer, PWM

Specifications apply to the complete model numbers shown. Connector, cable, signal and operating characteristics can change with the model suffix.

Delta PFR Fans for GPU Servers

The PFR Series provides high airflow and static pressure in commonly used 38 mm frame depths. It is suitable for servers that require strong cooling without the additional depth of an 80 mm fan assembly.

PFR0612XHE-SP00

PFR0612XHE-SP00 is a 60 × 60 × 38 mm fan providing 76.16 CFM and 3.185 inH₂O. Its compact dimensions and high speed make it suitable for dense server chassis where airflow must pass through narrow component channels.

Typical uses include:

  • Compact GPU nodes

  • 1U server platforms

  • Server power modules

  • High-density storage controllers

  • Localized accelerator cooling

PFR0812XHE-SP00

PFR0812XHE-SP00 uses an 80 × 80 × 38 mm frame and provides 134.29 CFM with 3.000 inH₂O static pressure.

It offers a useful balance between fan diameter, airflow and pressure for:

  • GPU compute servers

  • Multi-accelerator systems

  • Storage and AI inference appliances

  • Network computing platforms

  • Dense 2U chassis

PFR0912XHE-SP00

PFR0912XHE-SP00 provides 185.55 CFM in a 92 × 92 × 38 mm frame. Its larger diameter supports higher airflow while maintaining 2.523 inH₂O maximum pressure.

It can be considered for:

  • Larger GPU servers

  • AI training nodes

  • High-performance computing systems

  • Storage servers with restrictive drive cages

  • Rear fan-wall cooling

PFR1212DHE-SP00

PFR1212DHE-SP00 provides 254.34 CFM from a 120 × 120 × 38 mm frame. It is suitable for larger chassis where a 120 mm fan can be accommodated and high total airflow is required.

The 4-wire SP00 configuration provides tachometer feedback and PWM speed control, allowing the server controller to adjust fan speed according to thermal load.

Delta PFB-E Fans for Higher System Resistance

Delta’s E Series is designed for next-generation server architectures and power modules requiring increased static-pressure performance.

PFB0812EE-E uses an 80 × 80 × 80 mm frame and provides:

  • 129.56 CFM airflow

  • 6.010 inH₂O static pressure

  • 16,800 RPM speed

  • 48 W rated power

  • Tachometer feedback

  • PWM control

Compared with a conventional 38 mm fan, the deeper frame requires substantially more installation space. It should be considered when the chassis can accommodate 80 mm depth and the system pressure requirement exceeds the capability of a standard fan wall.

Delta GFB-E Fans for Extreme Pressure

GFB-E models provide very high static pressure in 40 mm, 60 mm and 92 mm frame sizes with a 56 mm depth.

GFB0612ES-E reaches a maximum static pressure of 9.730 inH₂O while maintaining 76.51 CFM free-air flow. This makes it suitable for compact systems with exceptionally restrictive airflow paths.

Potential applications include:

  • High-density server blades

  • Compact accelerator modules

  • High-impedance heat sinks

  • Power modules

  • Restricted GPU airflow channels

  • Next-generation computing platforms

The additional pressure comes with higher power consumption and acoustic noise. GFB0612ES-E is rated at 49.8 W and 82 dB(A), so the power circuit, mechanical structure and operating environment must be designed accordingly.

Can a Lower-Pressure Fan Replace a High-Pressure Server Fan?

A lower-pressure fan may have the same dimensions, voltage and connector but still provide insufficient airflow at the server operating point.

Possible results include:

  • GPU temperature increase

  • Processor thermal throttling

  • Memory or VRM overheating

  • Higher speed demand from the remaining fans

  • Fan alarms

  • Reduced system reliability

  • Emergency shutdown

Replacement should be based on the complete pressure–airflow curve, not only the frame size or free-air CFM.

Delta GPU and AI Server Fan Support

DataStorageIC supplies Delta high-static-pressure fans for GPU servers, AI computing systems, storage platforms and high-performance computing equipment.

To request pricing or confirm a replacement, please provide:

  • Complete Delta model and suffix

  • Required quantity

  • Photo of the original fan label

  • Connector and wire photos

  • Server type or chassis size

  • Required airflow or static pressure

  • Available installation dimensions

  • Requested delivery date

We can assist with PFR, PFB-E and GFB-E model comparison, pressure and airflow evaluation, connector matching, PWM compatibility, stock status and lead-time confirmation.

Contact DataStorageIC for Delta GPU and AI server fan pricing and engineering selection support.