Home > Power > PICO power modules > Pico DC2B-48S 700–1200V to 48V 300W DC-DC Converter

Pico DC2B-48S 700–1200V to 48V 300W DC-DC Converter

2026-09-24 10:58:07 DataStorage View times 3
Pico DC2B-48S 700–1200V to 48V 300W DC-DC Converter

Mfr. Part #: DC2B-48S

Manufacturer: Pico Electronics

Product Type: Isolated Regulated High-Power DC-DC Converter

Package: Through-Hole Full-Brick, 4.6 × 2.5 × 0.8 in, Aluminum Baseplate

Applications: High-voltage DC distribution, isolated 48V power rails, industrial power conversion, aerospace and defense systems, battery/DC-link equipment and test instrumentation

Description: 300W isolated regulated DC-DC converter with a 700–1200VDC input, 48V/6.25A output, 4242VDC isolation, remote sense and baseplate conduction cooling.


Contact us for current stock, pricing and lead time.

Get Price & Availability

Pico DC2B-48S 700–1200V Input 48V 300W DC-DC Converter

The Pico DC2B-48S is an isolated and regulated high-power DC-DC converter designed to convert a 700–1200VDC input bus into a 48VDC output. It delivers up to 300W and 6.25A, making it suitable for high-voltage DC distribution systems that require an isolated 48V rail.

The module uses a full-brick through-hole package with an aluminum baseplate for conduction cooling. Remote-sense terminals compensate for voltage drop between the converter and load, while integrated protection covers input under/overvoltage, output overcurrent, short circuit and overtemperature conditions.

Key Specifications

ParameterSpecification
ManufacturerPico Electronics
Part NumberDC2B-48S
SeriesDC2B
Converter TypeIsolated regulated high-power DC-DC converter
Nominal Input Voltage900VDC
Input Voltage Range700–1200VDC
Output Voltage48VDC
Output Current0–6.25A
Maximum Output Power300W
Typical Efficiency82% at nominal input and full load
Output Ripple500mVp-p maximum, 1MHz bandwidth
Output Voltage Tolerance±0.5%
Line Regulation±0.5% typical
Load Regulation±1% typical, 10–100% load
Input-to-Output Isolation4242VDC minimum
Input/Output-to-Baseplate Isolation2121VDC minimum
Operating Frequency100kHz typical
Remote-Sense CompensationUp to 1VDC
Operating Temperature0°C to +85°C baseplate
Optional Extended Temperature−40°C to +85°C; confirm ordering option
Storage Temperature−55°C to +105°C
CoolingConduction through baseplate
MountingThrough-hole
PackageFull-brick with aluminum baseplate
Dimensions4.6 × 2.5 × 0.8 in
WeightApproximately 340g

The 0°C to +85°C rating refers to the module’s baseplate temperature, not unrestricted ambient operation. The required heatsink, airflow and thermal interface must be calculated from actual input voltage, output load and ambient conditions.

Applications

Potential applications for the DC2B-48S include:

  • High-voltage DC distribution systems

  • Isolated 48V power rails

  • Industrial power-conversion equipment

  • Aerospace and defense power systems

  • High-voltage battery and DC-link systems

  • Ground-support and test equipment

  • High-power instrumentation

  • Systems requiring isolation between a high-voltage bus and 48V loads

Application suitability must be confirmed at the system level. The converter’s electrical specifications do not automatically indicate compliance with a particular railway, aerospace, automotive or safety standard.

When to Choose the DC2B-48S

Choose the Pico DC2B-48S when the system requires:

  • A continuous input range between 700VDC and 1200VDC

  • A regulated 48V output

  • Up to 6.25A or 300W output

  • High input-to-output isolation

  • Remote sensing at a physically separated load

  • Baseplate conduction cooling

  • A mechanically secured full-brick module

  • Reverse-polarity and input-voltage protection

  • Continuous short-circuit protection with automatic recovery

Do not select the DC2B-48S only because the nominal bus is close to 700V. Engineers should include source tolerance, startup overshoot, regenerative voltage and transient conditions. If the input can fall below 700V, the DC2A-48S may be more appropriate.

At 300W output and 82% typical efficiency, the module can dissipate approximately 66W internally. Thermal design is therefore a required part of the selection process.

Related Model Comparison

ModelInput RangeNominal InputOutputMaximum PowerBest Selection Reason
DC1-48S120–370VDC200VDC48V / 6.25A300WLower-voltage DC input bus
DC2A-48S350–700VDC500VDC48V / 6.25A300WMedium-voltage DC input bus
DC2B-48S700–1200VDC900VDC48V / 6.25A300WHigh-voltage DC input bus
DC2B-28S700–1200VDC900VDC28V / 10.71A300WSame input range with 28V output
DC2B-24S700–1200VDC900VDC24V / 12.5A300WSame input range with 24V output
DC2B-100S700–1200VDC900VDC100V / 2.5A250WHigher output voltage

DC1-48S, DC2A-48S and DC2B-48S provide the same 48V/300W output but cover different input-voltage ranges. Input-bus voltage is therefore the primary selection factor.

Equivalent and Alternative Models

There is no universal drop-in replacement for the DC2B-48S. A substitute must be checked for input range, isolation, pinout, package dimensions, remote-sense wiring, thermal interface and baseplate-temperature rating.

Possible Pico alternatives include:

  • DC2A-48S: For a 350–700VDC input bus.

  • DC1-48S: For a 120–370VDC input bus.

  • DC2B-28S: For a 28V output at up to 300W.

  • DC2B-24S: For a 24V output at up to 300W.

  • DC2B-100S: For a 100V output at up to 250W.

  • Pico custom configuration: For special input voltage, output voltage, isolation or power requirements.

For a system powered from a nominal 365V PFC bus, DC2A-48S is generally the relevant family member—not DC2B-48S—because 365V is below the DC2B operating range.

Related Products and Guides

Stock, Price and RFQ

DataStorageIC supports Pico DC2B-48S stock checking, pricing, datasheet confirmation and factory lead-time orders.

For an accurate quotation, please provide:

  • Full part number: DC2B-48S

  • Required quantity

  • Target delivery date

  • Actual input-voltage range

  • Output load and ambient conditions

  • Cooling method

  • Extended-temperature or screening requirements

Request DC2B-48S Price and Availability

Because the DC2B-48S handles up to 1200VDC, engineers should confirm insulation spacing, grounding, fusing, input protection, thermal design and applicable safety requirements before installation.

Frequently Asked Questions

Does the DC2B-48S require a heatsink?

The module is cooled by conduction through its baseplate. Whether a separate heatsink and forced airflow are required depends on load, input voltage and ambient temperature. At full 300W output, a properly designed thermal path is normally required.

Can the DC2B-48S operate from a 600VDC input?

No. Its specified input range begins at 700VDC. For a bus operating between 350VDC and 700VDC, compare the DC2A-48S instead.

What does the remote-sense function do?

Remote sensing compensates for voltage loss in the wiring between the converter and load. The DC2B-48S can compensate for up to 1V of cable drop. For local sensing, the sense terminals must be connected to the corresponding output terminals according to the datasheet.




WhatsApp

WhatsApp

Email

Email

RFQ

RFQ

Facebook

Facebook