PFR1212UHE-SP00 Delta 12V High-Airflow PWM Cooling Fan
Part Number: PFR1212UHE-SP00
Manufacturer:Delta Electronics
Series: PFR
Product Type: DC axial cooling fan
Rated Voltage: 12V DC
Frame Size: 120 × 120 × 38mm
Bearing Type: Ball bearing
Control Function: PWM speed control
Speed Feedback: Tachometer output
Termination: 4 lead wires
Part Status: Active
Stock: Contact us for current availability and lead time
Delta PFR1212UHE-SP00 12V High-Airflow PWM Cooling Fan
The PFR1212UHE-SP00 is a high-performance DC axial fan from Delta Electronics’ PFR series. It features a standard 120 × 120 × 38mm frame, a rated voltage of 12V DC and a maximum speed of 6,600 RPM.
The fan delivers up to 228.65 CFM airflow and 1.206 inchH₂O static pressure, making it suitable for servers, storage systems, telecom equipment and industrial electronics with high heat density or restrictive airflow paths.
The SP00 version uses four lead wires and supports both PWM speed control and tachometer speed feedback. This enables the host controller to adjust cooling performance according to system temperature while monitoring fan operation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Rated voltage | 12V DC |
| Operating voltage range | 8.0–13.2V DC |
| Rated current | 2.70A |
| Rated power | 32.40W |
| Frame dimensions | 120 × 120 × 38mm |
| Fan type | DC axial fan |
| Maximum speed | 6,600 RPM |
| Maximum airflow | 228.65 CFM / 6.475m³/min |
| Maximum static pressure | 1.206 inchH₂O / 30.636mmH₂O |
| Noise level | 65.5dB(A) |
| Bearing type | Ball bearing |
| Control function | PWM speed control |
| Monitoring function | Speed sensor / tachometer |
| Termination | 4 lead wires |
| Operating temperature | −10°C to +70°C |
| Expected lifetime | 70,000 hours at 40°C |
| Weight | Approximately 410g |
| Frame material | Plastic |
| Blade material | Plastic |
| Ingress protection | Not specified |
The airflow and static-pressure specifications are maximum values measured at different points on the fan performance curve. Actual airflow depends on the resistance of the complete cooling system, including heat sinks, filters, grilles, cables and ventilation channels.
Typical Applications
The Delta PFR1212UHE-SP00 can be used in:
AI, GPU and high-density computing servers
Enterprise servers and data-center equipment
RAID, NAS and disk-array storage systems
Network switches and telecom equipment
Industrial computers and edge servers
Power supplies, rectifiers and electronic loads
Battery energy-storage control systems
Automation and test equipment
High-density electronic cabinets
Temperature-controlled cooling systems
PWM Speed Control and Tachometer Feedback
The PFR1212UHE-SP00 provides two separate system-management functions:
PWM control: Allows the host controller to adjust fan speed according to temperature or workload.
Tachometer feedback: Provides a speed signal for fan monitoring, fault detection and system alarms.
PWM control can reduce unnecessary power consumption and acoustic noise when full cooling performance is not required. Under high thermal load, the controller can increase fan speed to improve airflow.
The controller’s PWM voltage, frequency and logic requirements must match the fan specification. Connector type and pin assignment should also be confirmed before installation.
Cooling Performance
With maximum airflow of 228.65 CFM and maximum static pressure of 30.636mmH₂O, the PFR1212UHE-SP00 is designed for cooling restrictive equipment structures containing:
Dense heat-sink fins
Multiple server drive bays
Air filters and protective grilles
Closely spaced circuit boards
Cable bundles and narrow air channels
High-power processors, GPUs and power modules
For systems with substantial airflow resistance, static-pressure capability is as important as free-air airflow. A lower-pressure fan with the same frame size may not provide sufficient airflow after installation.
Power Supply and Noise Considerations
The fan draws 2.70A and consumes approximately 32.40W at its rated operating point. The 12V power supply, PCB traces, wiring and connector must support the fan’s operating current and startup requirements.
With a specified noise level of 65.5dB(A), this model is intended primarily for server rooms, data centers, telecom installations and industrial equipment. It is generally not suitable for noise-sensitive office or consumer applications.
PFR1212UHE-SP00 Replacement Selection
Before replacing the PFR1212UHE-SP00, confirm the following parameters:
Complete part number: PFR1212UHE-SP00
Rated voltage: 12V DC
Operating voltage range: 8.0–13.2V DC
Frame size: 120 × 120 × 38mm
Rated current: 2.70A
Four-wire PWM and tachometer interface
Airflow and static-pressure requirements
Connector type and pin sequence
Wire length and mounting dimensions
Airflow direction and installation orientation
A fan with the same dimensions and voltage is not automatically a direct replacement. Differences in current, pressure, PWM interface, tachometer signal, connector and pin assignment can affect equipment operation.
The SP00 suffix is important because it identifies the PWM-controlled configuration. Do not substitute a two-wire or three-wire version unless the host equipment does not require PWM control and the electrical interface has been verified.
Stock, Pricing and Lead Time
DataStorageIC can assist with sourcing the original Delta PFR1212UHE-SP00, compatible suffix versions and technically matched replacement fans.
For an accurate quotation, please provide:
Required quantity
Target delivery date
Shipping destination
Clear photograph of the fan label
Connector and wire photograph
Wire length and pin sequence
Equipment model or application
Required inspection or traceability documents
Contact us for current stock, price, lead time, datasheet support and replacement-model evaluation.